The nozzle is the smallest part of a misting system — and it decides how the whole system performs. Orifice size, together with pump pressure, sets droplet size and flow.
Rule of thumb for high-pressure systems
- 0.1 mm: very fine fog for humidification, greenhouses and indoor work. Needs the cleanest water.
- 0.2 mm: fine mist that evaporates quickly — the usual choice for humid coastal sites.
- 0.3 mm: more flow and wider spread — good for hot, dry inland sites and larger areas.
Spacing and pressure
Nozzles are commonly spaced 40–60 cm apart on cooling lines. The pump must be sized for the total flow of all nozzles at the design pressure; too many nozzles for the pump lowers pressure and produces larger, wetter droplets.
Anti-drip and cleaning
- Use anti-drip nozzles and an auto-drain valve so lines do not dribble after shutdown.
- Clean nozzles by soaking in nozzle cleaner for 30–60 minutes, rinsing and refitting.
- Protect nozzles with proper filtration.